Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Korean Journal of Blood Transfusion ; : 39-42, 2023.
Article in English | WPRIM | ID: wpr-977184

ABSTRACT

We would like to introduce domestic subscribers of the Korean Journal of Blood Transfusion to the important aspects to be considered while selecting a reference allele and reporting a new allele candidate. ABO*A1.02 has only a single nucleotide substitution of c.467C>T in ABO*A1.01, and when ABO*A1.01 is used as the reference allele, the ABO*AW.10 allele should be marked as having both c.467C>T and c.784G>A variants. Unfortunately, it has not been modified as such in the ISBT database. For this reason, in the journal Transfusion (2020), the official journal of the Association for the Advancement of Blood Biotherapies, there was a report of a new allele with c.467C>T and c.784G>A variants. Cases of ABO*AW.10 allele with a weak A phenotype are not uncommon in Koreans, and it is necessary to accurately mark the reference allele. The blood type A reference allele of the International Society of Blood Transfusion (ISBT) database currently used for ABO alleles reporting is based on ABO*A1.01. Therefore, it should be considered that the ABO*AW.10 allele has both the c.467C>T and c.784G>A variants together.

2.
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 523-526, 2007.
Article in Korean | WPRIM | ID: wpr-161836

ABSTRACT

PURPOSE: Globe displacement due to a blowout fracture is a rare clinical phenomenon. The authors present reduction of a globe displacement to the maxillary sinus due to trauma suffered in a fall and the reconstruction of a large defect left in the medial and inferior orbit. METHODS: A 39-year-old male patient was unable to open his left eye after being struck on the periorbital area by a metal edge. Laceration was not noted in that area but we were unable to observe the intraorbital globe. A facial computed tomography (CT) scan showed that the globe was displaced through the maxillary sinus. A transconjunctival approach was used to access the infraorbital margin and the globe entrapped in the inferior margin of the orbit was successfully reduced. A large defect in the medial and inferior orbit was reconstructed using a graft from the iliac bone. RESULTS: In 5 months after the operation, no atrophy of the globe was seen. Both sides retained a similar shape. A satisfactory functionality outcome in terms of improved extraocular muscle movement, and a satisfactory aesthetical outcome were achieved. CONCLUSION: The authors report the reduction of a globe displaced to the maxillary sinus following a fall and the reconstruction of the large defect left in the medial and inferior orbit.


Subject(s)
Adult , Humans , Male , Atrophy , Lacerations , Maxillary Sinus , Orbit , Transplants
SELECTION OF CITATIONS
SEARCH DETAIL